Ensure excellent tissue processing quality as tissue are processed in a fully enclosed environment and under Vacuum.

Medimeas Vacuum tissue processor is designed for excellent performance and reliability with feature like Stirrer in retort for better infiltration of tissue sample and multi programmable memory gives flexibility to operator to select different programs depending on tissue type.

Floor standing tissue processor processing upto 300 cassettes
User can select cycle with vacuum
Metal tissue basket specially design to avoid sticking of basket
distinct fill levels with sensor in processing chamber to shorten processing time
Fully automatic and programmable reagent management system
Comprehensive monitoring & full process control
Inbuilt password protected area
Ability to interface with LIS system
Reagent storage cabinet is built to enhance safety standard and is vented through two additional filters for further fume control
Systematic logging and reporting of quality control data, event records and program inform in the quoted model
Specimen safety and protection is accomplished by in built battery back up of 40 minutes in hour
Auto cleaning cycle, efficient paraffin wax cleaning system to extract solvent contaminants to increase wax life.
Colour touch screen LCD display of cycles, reagents levels, date & time user friendly softwares
Continuous agitation circulates reagents freely around specimens
Alarm system, password protected, instrument supervisor mode
Optional barcode reader
Micro-processor based auto memorization and recovery.
Automatic in- process reagent rotation no manual handling of reagents
Low reagent alarm system. Remote alarm to signal possible problems and reagent change.
Warning alarm for trouble free operation
Remote fill & drain system
Compatible with standard reagent system
Disposable wax tray system makes wax replacement clean and simple
Automatic/Manual functioning mode.
Protection from overheating and excessive vacuum and pressure
Vacuum & fume control system, running rapid biopsy protocol
Possibility of interrupting an automatic process for reloading or removing cassettes for application before the end of a run
Retort filling time selectable
Filling time user selectable from 4 to 7 mins
Inbuilt reagent level sensor to deduct reagent level during processing
Suitable tissue flotation water bath will be provided
Machine pre-test after starting the program to confirm that all lines and valves are un-blocked working fine
Processing retort volume tissue penetration and processing
Machine have inability cleaning cycle after ending program to clean the wax from retort and pipes to increase reagent

Technical Specification
PROCESSING RETORT
Maximum Capacity 300/400 cassettes
Retort Material Stainless Steel
Processing Retort Volume 5 litres
Temperature(Parafin) 40 to 70oC
Temperature (Cleansing Reagent)40-67oC
Temperature(Reagent) 35oC to 60oC
Temperature Accuracy ±10oC
Vacuum -70kPa
Pressure +35kPa
Time Selectable Range of each stn.0 to 99 hrs, 59 mins
PARAFFIN BATHS
No. of Baths 3
Volume 4 litres each
Average Melting Time 3hrs approx
REAGENT BOTTLES
No. of Bottles 10
Bottle Volume 5 litres each
CLEANING BOTTLES
No. of Bottles 3
Bottle Volume 4 litres each
GENERAL
Delay Time Upto 7 days
Voltage 220V @ 50-60Hz
Overall Dimensions 620x680x1280mm